All electrical work must be carried out by a properly licensed electrician, in compliance with
local electrical standards. Failure to observe this point will void the factory warranty for the Tempest
Enclosure.
1 Switch off power to the branch circuit, carefully following lockout and tag-out procedures. Failure to do so
could cause serious injury or death.
2 You will need two electrical junction boxes, located within a short distance from the enclosure, one for power,
one for DMX control. Use outdoor-rated flexible conduit between the box and the enclosure.
3 AC and control circuits must be wired in separate conduits.
The conduit entry holes accept US ½” conduit fittings, and
international 20-22mm (OD) conduit fittings.
For temporary installations, use a suitable cable and clamp in the
same openings.