Tempest Tornado Bedienungsanleitung

Stöbern Sie online oder laden Sie Bedienungsanleitung nach Projektoren Tempest Tornado herunter. Tempest Tornado User Manual Benutzerhandbuch

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 50
  • Inhaltsverzeichnis
  • FEHLERBEHEBUNG
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 0
Cyclone Enclosure User Manual page 1
User Manual and Installation Guide
Tornado Moving Light Enclosures
Tempest Lighting, Inc.
13110 Saticoy Street, Unit C
N. Hollywood, CA 91605, USA
Tel +1 818 787 8984
Fax +1 818 982 5510
www.tempest.org
For the following products, manufactured after
August 2013
Tornado 1900, 1950
Tornado 2000, 2100
Tornado 2200, 2300
Tornado 2400
With DEC3.3 Goldilocks
TM
rev 0.01.006 or higher
In the interest of continuous product improvement, the information in this document is subject to change without
notice. Neither Tempest Lighting, Inc. nor its representatives or agents may be held liable for expense or injury
arising from it.
© Tempest Lighting Inc. All Rights Reserved September, 2013
Lamp
Heater Fan RelayOn DMXTemp
ESC OK
User Manual
Tornado Moving Light
Enclosures
Seitenansicht 0
1 2 3 4 5 6 ... 49 50

Inhaltsverzeichnis

Seite 1 - User Manual

Cyclone Enclosure User Manual page 1 User Manual and Installation Guide Tornado Moving Light Enclosures Tempest L

Seite 2 - Table of Contents

Cyclone Enclosure User Manual page 10 2 Installation Safety and Warnings  Read the Manual before installing the enclosure  Read the manua

Seite 3

Cyclone Enclosure User Manual page 11 Planning  Snow clearance:  Enclosure must be powered 24/7/365.  Warning: This ins

Seite 4 - Tempest Lighting, Inc

Cyclone Enclosure User Manual page 12 Pipe Mounting Pipe Clamps 4900.MCT Pipe clamp, for pipes 1.5” (38mm) to 2” (50mm) OD. Order TWO

Seite 5

Cyclone Enclosure User Manual page 13 Mounting plate Guidelines Use ¼” (6mm) or greater galvanized steel or stainless steel plate. Do not obst

Seite 6 - 1 Introduction

Cyclone Enclosure User Manual page 14 Orientation Guidelines Tornado 1900.xx Tornado 1950.xx Tornado 2000.xx Tornado 2100.xx Tornado

Seite 7 - Dimensions

Cyclone Enclosure User Manual page 15 Drainage For base up/globe down or horizontal operation, a small drainage hole will be drilled in the glo

Seite 8 - Tornado 2400

Cyclone Enclosure User Manual page 16 Installation above public Spaces If the Tornado enclosure is to be installed above an area accessible to

Seite 9 - Note - Marine Latches

Cyclone Enclosure User Manual page 17 3 Wiring and Control  All electrical work must be carried out by a properly licensed electrician, in c

Seite 10 - 2 Installation

Cyclone Enclosure User Manual page 18 One or Two Power Circuits? Single Feed Split Feed Tempest enclosures may be wired on single or do

Seite 11 - Mounting – Tornado 1900-1950

Cyclone Enclosure User Manual page 19 Split Feed Connections Note: wire colors may differ depending on applicable electrical standards. Europea

Seite 12

Cyclone Enclosure User Manual page 2 Table of Contents 1 Introduction ...

Seite 13 - Mounting plate Guidelines

Cyclone Enclosure User Manual page 20 4 Digital Enclosure Control DEC3.3TM with GoldilocksTM DEC3.3TM – that’s Digital Enclos

Seite 14

Cyclone Enclosure User Manual page 21 DEC3.3 Schematic OUT OUTIN INDMX/RDM – RS485AC FAN(S)AC HEATER(S)SENSORCut links on board for split fe

Seite 15 - Drainage

Cyclone Enclosure User Manual page 22 DEC3.3 Main Functions 1 Sense current to luminaire (lamp on/off) 2 Record lamp hours 3 Monitor tempera

Seite 16

Cyclone Enclosure User Manual page 23 Operating Modes DEC3.3 may operate in one of four modes, set using either the Front Panel or by RDM contr

Seite 17 - 3 Wiring and Control

Cyclone Enclosure User Manual page 24 DEC3.3 Control Parameters Temperature and Humidity Ranges: Notes: 1 In moving light enclos

Seite 18 - One or Two Power Circuits?

Cyclone Enclosure User Manual page 25 without changing the air in the enclosure. Lamp on point may be set in 0.2 Amp increments between 0.2 Amp

Seite 19 - E L N

Cyclone Enclosure User Manual page 26 Note: If the enclosed equipment does not use DMX, then connector (2) on the controller is DMX OUT for the

Seite 20 - Heater Fan RelayOn DMXTemp

Cyclone Enclosure User Manual page 27 Remote Device Management (RDM) RDM refers to ANSI E1.20, a control protocol in the entertainment industr

Seite 21 - OUT OUTIN IN

Tornado Enclosure User Manual page 28 Control Interface LED Indicators Heater ON (Green) Heater is ON, to maintain lower temperature lev

Seite 22 - DEC3.3 Main Functions

Tornado Enclosure User Manual page 29 Control Display The display on the Control display provides additional status information, depending on t

Seite 23 - Operating Modes

Cyclone Enclosure User Manual page 3 Mounting the Luminaire – Tornado 2400 ... 41 6 Closing up t

Seite 24 - DEC3.3 Control Parameters

Tornado Enclosure User Manual page 30 Control Menu SET DMX OPTIONS SET DMX MODE From the Front Panel, this menu item allows the user to check

Seite 25 - DMX Connections

Tornado Enclosure User Manual page 31 SET DMX RESPONSE DMX Response sets a delay time before DMX Control Mode settings are acted on. Setting a

Seite 26

Tornado Enclosure User Manual page 32 STATUS DISPLAY View current status information, using the arrow keys to scroll through: a) Humidity – re

Seite 27 - RDM and RDM Integration

Tornado Enclosure User Manual page 33 This view shows a single DEC3.2 test unit that has been correctly discovered and labeled by the GetSet so

Seite 28 - Control Interface

Tornado Enclosure User Manual page 34 5 Mounting the Luminaire  Do not attempt to mount the luminaire with only a single person. 1 Remo

Seite 29

Tornado Enclosure User Manual page 35 Tornado 1900-1950 Mount the luminaire on its omega clamps on the fixture mounting Bracket. Note: Dependi

Seite 30 - Control Menu

Tornado Enclosure User Manual page 36 Tornado 2000, 2100, 2200, 2300 Fixture Tray Use either the vertical or horizontal

Seite 31

Tornado Enclosure User Manual page 37 Luminaires with Omega Clamps This applies to most luminaire types: 1. Remove the Fixture tray from the

Seite 32

Tornado Enclosure User Manual page 38 Vari*Lites and the Vari*Lite Hook Bracket Vari*Lites are provided with a Hook Bracket in place of an Omeg

Seite 33 - Firmware Upgrade over RDM

Tornado Enclosure User Manual page 39 Martin MAC III and other tall Luminaires The MACIII is too tall to use in a Tornado 2300 with Omega Clam

Seite 34 - 5 Mounting the Luminaire

Cyclone Enclosure User Manual page 4 CERTIFICATE AND DECLARATION OF CONFORMITY FOR CE MARKING Tempest Lighting, Inc. 13110 Saticoy St

Seite 35 - Tornado 1900-1950

Tornado Enclosure User Manual page 40 Shorter Luminaires Requiring Bracket Standoffs In order to align the center of the luminaire correctly in

Seite 36 - Fixture Tray

Tornado Enclosure User Manual page 41 Mounting the Luminaire – Tornado 2400 The Tornado 2400 is designed to house the Barco/High End Systems Sh

Seite 37

Tornado Enclosure User Manual page 42 6 Closing up the Enclosure 1 Check all electrical connections 2 Clear the enclosure and luminaire of

Seite 38

Tornado Enclosure User Manual page 43 Securing the Globe to the Tornado Enclosure Base 1. Using two people, lift the globe assembly in place.

Seite 39

Tornado Enclosure User Manual page 44 7 Operation  Enclosure must receive power at all times. It is an active, climate-controlled enclosure,

Seite 40

Tornado Enclosure User Manual page 45 8 Routine Maintenance It is very important to perform routine maintenance on both the enclosure and the

Seite 41

Tornado Enclosure User Manual page 46 cleaned with any mild cleaner. It is also acceptable to treat globe with a product that keeps rain from a

Seite 42 - Enclosure

Tornado Enclosure User Manual page 47 9 Troubleshooting This is a guide to the general symptoms, problems, and solutions that may occur during

Seite 43

Tornado Enclosure User Manual page 48 Latches do not latch properly.  Closure of globe may be obstructed. Check to make sure seals are clear

Seite 44 - 7 Operation

Tornado Enclosure User Manual page 49 10 Limited Warranty All sales are subject to the company’s Standard Terms and Conditions, available for

Seite 45 - 8 Routine Maintenance

Cyclone Enclosure User Manual page 5 This is to certify that the following products Tornado 2000.US(H,V) Lighting Enclosure Tornado 2

Seite 46

Tornado Enclosure User Manual page 50 11 Tempest Product Support Step 1: First contact your local Dealer for support. Your dealer is best pl

Seite 47 - 9 Troubleshooting

Cyclone Enclosure User Manual page 6 1 Introduction Using This Manual Please read this manual in its entirety before starting work. All the

Seite 48

Cyclone Enclosure User Manual page 7 Dimensions CAD drawings in DWG and PDF format are available for download at www.tempest.org Tornado 1900

Seite 49 - 10 Limited Warranty

Cyclone Enclosure User Manual page 8 Tornado 2200-2300 Tornado 2400

Seite 50 - 11 Tempest Product Support

Cyclone Enclosure User Manual page 9 Note – Draw Latch Clearance Allow adequate clearance for all latches. Note - Marine Latches M

Kommentare zu diesen Handbüchern

Keine Kommentare